ALUMINUM SPECIFICATIONS
Tolerance, Inches
|
||
Pipe
Size Inches |
Allowable deviation
of mean1 diameter from nomial diameter. Difference between
1/2 (AA + BB) and nominal diameter |
Allowable deviation
of diameter at any point from nominal diameter. Difference between
AA and nominal diameter |
Schedule 5 and 10
|
Schedule 20
and greater |
|
Under 2
|
+.015 – .031
|
+.015 – .031
|
2-4
|
+.031 – .031
|
+1% – 1%
|
5-7
|
+.062 – .031
|
+1% – 1%
|
8-12
|
+.093 – .031
|
+1% – 1%
|
WALL THICKNESS — PIPE
Schedule
Number |
Tolerance
|
Allowable deviation of wall thickness
at any point from nominal wall thickness |
|
5 and 10
|
±12-1/2%, ±0.12 in. min.
|
20 and greater
|
-12-1/2%2
|
WEIGHT — PIPE
Schedule
Number |
Tolerance
|
Allowable deviation
from theoretical weight |
|
5 and 10
|
For schedule 5 and 10, only diameter, wall thickness, and length tolerances apply.
|
20 and greater
|
+8%
|
1 Mean diameter is the average of any two diameter measurements taken at right angles to each other at any point along the length.
2 Maximum wall thickness is controlled by weight tolerance
3 For schedule 5 and 10, only diameter, wall thickness, and length tolerances apply.
4 Minimum weight is controlled by tolerances for outside diameter and wall thickness.
LENGTH — PIPE
Specified
length Ft |
Tolerance, Inches plus
|
Allowable deviation
from theoretical length |
|
Up thru 20
|
1/4
|
Over 20 thru 40
|
1/2
|
STRAIGHTNESS — PIPE
Pipe
size Inches |
Tolerance5, Inches
|
Allowable deviation from straight
|
|
In total length or in any
measured segment of one ft. or more of total length |
|
Under 6
|
.010 x measured length, ft.
|
6 thru 12
|
.020 x measured length, ft.
|
STANDARD WELDING BEVELS — PIPE
DOUBLE BEVEL
For wall thickness over 0.750 in. |
STRAIGHT BEVEL
For wall thickness 0.750 in. and less |
|
|
When weight of pipe on flat surface minimizes deviation.